Home » Liquid Filtration » Reverse Osmosis Systems

Reverse Osmosis SystemsSeries R14 RO

If your water or chemical process must be extremely clean and Nanofiltration systems are not up to the task then you need a Reverse Osmosis System. These systems use special membranes to reject metals, salts and organic impurities down to the molecular level. This RO water filtration process leaves your liquids with an extraordinarily high purity level and the confidence that your application will not be disrupted by impurities.

Watt's reverse osmosis water filtration system is designed to provide the commercial and industrial user with the most trouble free, cost effective and reliable form of water treatment available, by providing every option necessary for a successful installation. With several different options available, these systems can treat from 150 to 6,600 Gallons per day. However, larger units, along with accessory options such as mounting legs and water tanks, are available upon request.

Standard Features:

  • Powder coated steel frame
  • Inlet solenoid valve
  • 20” prefilter
  • Prefilter pressure gauge
  • Multistage centrifugal pump
  • Low-pressure protection with microprocessor auto reset
  • 2 ½” liquid filled pump pressure gauge
  • Stainless steel pressure vessel(s)
  • Product flow meter
  • Reject flow meter
  • Concentrate needle valve
  • Non metallic recycle needle valve
  • On / off toggle switch
  • Feed water and product water TDS monitor

Product Files

R4X40 Series Whole House RO System Brochure
R4X40 Series Whole House RO System IOM

Specifications

Membrane Size4" x 40"
Average membrane rejection98%
Feed water connection3/4" NPTF
Prefilter20"
Product water connection5/8" tubing OD
Reject water connection5/8" tubing OD
Feed water pressure (minimum)10 PSI
Electrical Requirement120 VAC 60 HZ

Available Models

R4X40-1R4X40-2R4X40-3
Maximum Productivity (gallons per day)2,2004,4006,600
Recovery (user adjustable)15 - 75%25 - 75%32 - 75%
Number of membranes123
Feed water required (maximum)10 GPM12 GPM14 GPM
Drain required (maximum)10 GPM12 GPM14 GPM
Motor horse power3/411-1/2
Electrical requirement15 amps20 amps25 amps
Dimensions W x D x H20 x 20 x 5020 x 20 x 5020 x 26 x 50
Shipping Weight (estimated lbs)120150180

Standard Features:

  • Stainless steel frame
  • Automatic inlet valve
  • Pre-filter housing and cartridge, 10″
  • Procon pump (brass)
  • 1/2 HP motor
  • Liquid filled pump pressure gauge (2-1/2″)
  • Stainless steel pressure vessels
  • Needle valve for concentrate line
  • Needle valve for recycle line
  • Check valve for product water (stainless steel)
  • Product pressure switch with Auto/Off
  • Low-pressure shut-off with automatic restart

Product Files

R-12 Wall-Mounted RO System Brochure
R-12 Wall-Mounted RO System IOM

Specifications

Product water & reject water connection (tubing)3/8"
Feed water requirement (maximum)2.4 GPM
Feed water pressure requirement (minimum)10 PSIG
Drain requirement (maximum)2.4 GPM
Electrical Requirement120 VAC 60 HZ
Amps8
Pump1/2 HP

Available Models

ModelGPDRecovery ( Adjustable)Membrane Size# of MembranesFeed Water ConnectionTypical RejectionDimensions
R12-0150-115015%-75%2-1/2"x14"11/2" NPT98%22"x32"x12"
R12-0150-215015%-75%2-1/2"x14"11/2" NPT98%22"x32"x12"
R12-0150-315015%-75%2-1/2"x14"11/2" NPT98%22"x32"x12"
R12-0250-125015%-75%2-1/2"x21"11/2" NPT98%22"x32"x12"
R12-0250-225015%-75%2-1/2"x21"11/2" NPT98%22"x32"x12"
R12-0250-325015%-75%2-1/2"x21"11/2" NPT98%22"x32"x12"
R12-0600-160015%-75%2-1/2"x40"11/2" NPT98%22"x52"x12"
R12-0600-260015%-75%2-1/2"x40"11/2" NPT98%22"x52"x12"
R12-0600-360015%-75%2-1/2"x40"11/2" NPT98%22"x52"x12"
R12-1200-1120025%-75%2-1/2"x40"21/2" NPT98%22"x52"x12"
R12-1200-2120025%-75%2-1/2"x40"21/2" NPT0.9822"x52"x12"
R12-1200-3120025%-75%2-1/2"x40"21/2" NPT0.9822"x52"x12"

Standard Features:

  • Powder coated steel frames
  • Inlet solenoid valve
  • Pre-filter
  • 1/2 HP motor
  • Brass pump
  • Liquid filled pre-filter pressure gauge
  • 2 1/2” liquid filled pump pressure gauge
  • Product water & reject water flow meters
  • High pressure, non-metallic membrane housings
  • SS needle valves for concentrate and recycle lines
  • Stainless steel product water check valve
  • On / off toggle switch
  • Low-pressure shut-off with auto restart
  • Feed water and product water TDS monitor

Product Files

R-13 Compact Wall Mount RO System Brochure
R-13 Compact Wall Mount RO System IOM

Specifications

Feed water connection3/4" NPTF
Product water connection3/8” Tubing OD
Reject water connection3/8” Tubing OD
Feed water required (max.)2.4 GPM
Feed water required (min.)10 PSI
Drain required (max.)2.4 GPM
Electrical requirements120 VAC 60 Hz
Amps8
Pump (H.P.)1/2

Available Models

R13-0250R13-0600R13-1200
Maximum Productivity (gallons per day)2506001,200
Average membrane rejection rate98%98%98%
Recovery (adjustable)8 - 75 %17 –75%34 - 75 %
Membrane size3” x 10”3” x 20”3” x 20”
Number of membranes112
Pre-filter (system ships with one 5 micron cartridge)10"20"20"
Dimensions, approximate (W x H x D)26" x 26" x 9" 26" x 36" x 9" 26" x 36" x 9"
Shipping Weight, estimated (lbs.)506075