CREx 020Explosion Proof Heater

The Explosion-Proof Heater CREx 020 use convection and are perfect for use in areas with explosion hazards. These heaters can maintain minimum operating temperatures and help prevent the failure of electronic components caused by condensation and corrosion.

ISC's enclosure heaters warm the air inside enclosures, preventing water vapor from condensing on components while providing the greatest possible air circulation with low energy consumption. Explosion-proof heaters are available from ISC and are compatible with special considerations like auto-ignition points in hazardous environments.

Click the "Get a Quote" button to have a specialist provide you with more information on the perfect heating option for your application.

Features:

  • Large convection surface
  • Maintenance free
  • DIN rail mountable
 

Specifications

Temperature ClassT3
Ex Protection type II 2 GD, Gases, DustsEx db IIC T3 Gb
Ex tb IIIC T200 °C Db IP66
Ambient temperature-76 to +185 °F (-60 to +85 °C)
Surface Temperaturemax. +392 °F (+200 °C)
Heating ElementHigh Performance Cartridge
Heating BodyAluminum Profile, Silver Anodized
Connectionsilicone cable (halogen-free) 3 x AWG 18 (0.75 mm²), length 3 ft (1 m)
Connection PEAWG 18 to 14 (0.75 to 2.5 mm²)
Mountingclip for 35 mm DIN rail, EN 60715 for heating body size - 4.7 x 2.4"; screw mounting with 2 mounting brackets for all heating body sizes, optional sideways mounting
Mounting PositionVertical Airflow (connection at bottom)
Storage Temperature-76 to +185 °F (-60 to +85 °C)
Operating / Storage humiditymax. 90 % RH (non-condensing)
Protection type / Protection classIP66 / I (grounded)
ApprovalsEPS 16 ATEX 1 109 X;
IECEx EPS 16.0048X; EAC

Models

Din Clip Mount Model No.Screw Mounting Bracket Model No.Hole Spacing XOperating
Voltage
Heating
Capacity
Pre-fuse
T (time-delay)
Dimensions
(DxWxH)
Weight
(approx)
02031.0-0002031.0-105.9"AC 230 V50 W0.5 A3.2 x 1.9 x 4.3"1.5 lbs
02031.9-0002031.9-105.9"AC 120 V50 W1 A3.2 x 1.9 x 4.3"1.5 lbs
02032.0-0002032.0-108.9"AC 230 V100 W1 A3.2 x 1.9 x 7.1"2.2 lbs
02032.9-0002032.9-108.9"AC 120 V100 W2 A3.2 x 1.9 x 7.1"2.2 lbs
02033.0-0002033.0-108.9"AC 230 V150 W1.5 A4.7 x 2.4 x 7.1"3.1 lbs
02033.9-0002033.9-108.9"AC 120 V150 W3 A4.7 x 2.4 x 7.1"3.1 lbs
02034.0-0002034.0-1011.8"AC 230 V200 W2 A4.7 x 2.4 x 9.5"3.7 lbs
02034.9-0002034.9-1011.8"AC 120 V200 W4 A4.7 x 2.4 x 9.5"3.7 lbs
-02035.0-1010.8"AC 230 V250 W2.5 A6.3 x 3.2 x 8.6"5.1 lbs
-02035.9-1010.8"AC 120 V250 W5 A6.3 x 3.2 x 8.6"5.1 lbs

Product Download

CREx020_T3

Specifications

Temperature ClassT4
Ex Protection type II 2 GD, Gases, DustsEx db IIC T4 Gb
Ex tb IIIC T135 °C Db IP66
Ambient temperature-76 to +122 °F (-60 to +50 °C)
Surface Temperaturemax. +275 °F (+135 °C)
Heating ElementHigh Performance Cartridge
Heating BodyAluminum Profile, Silver Anodized
Connectionsilicone cable (halogen-free) 3 x AWG 18 (0.75 mm²), length 3 ft (1 m)
Connection PEAWG 18 to 14 (0.75 to 2.5 mm²)
Mountingclip for 35 mm DIN rail, EN 60715 for heating body size - 4.7 x 2.4"; screw mounting with 2 mounting brackets for all heating body sizes, optional sideways mounting
Mounting PositionVertical Airflow (connection at bottom)
Storage Temperature-76 to +185 °F (-60 to +85 °C)
Operating / Storage humiditymax. 90 % RH (non-condensing)
Protection type / Protection classIP66 / I (grounded)
ApprovalsEPS 16 ATEX 1 109 X;
IECEx EPS 16.0048X; EAC

Models

Din Clip Mount Model No.Screw Mounting Bracket Model No.Hole Spacing XOperating
Voltage
Heating
Capacity
Pre-fuse
T (time-delay)
Dimensions
(DxWxH)
Weight
(approx)
02041.0-0002041.0-105.9"AC 230 V50 W0.5 A3.2 x 1.9 x 4.3"1.5 lbs
02041.9-0002041.9-105.9"AC 120 V50 W1 A3.2 x 1.9 x 4.3"1.5 lbs
02042.0-0002042.0-108.9"AC 230 V100 W1 A4.7 x 2.4 x 7.1"3.1 lbs
02042.9-0002042.9-108.9"AC 120 V100 W2 A4.7 x 2.4 x 7.1"3.1 lbs
-02043.0-1010.8"AC 230 V150 W1.5 A6.3 x 3.2 x 8.6"5.1 lbs
-02043.9-1010.8"AC 120 V150 W3 A6.3 x 3.2 x 8.6"5.1 lbs
-02044.0-1013.8"AC 230 V200 W2 A6.3 x 3.2 x 11.8"6.1 lbs
-02044.9-1013.8"AC 120 V200 W4 A6.3 x 3.2 x 11.8"6.2 lbs

Product Download

CREx020_T4

Specifications

Temperature ClassT5
Ex Protection type II 2 GD, Gases, DustsEx db IIC T5 Gb, Ex tb IIIC T100 °C Db IP66
Ambient temperature-76 to +122 °F (-60 to +50 °C)
Surface Temperaturemax. +212 °F (+100 °C)
Heating ElementHigh Performance Cartridge
Heating BodyAluminum Profile, Silver Anodized
Connectionsilicone cable (halogen-free) 3 x AWG 18 (0.75 mm²), length 3 ft (1 m)
Connection PEAWG 18 to 14 (0.75 to 2.5 mm²)
Mountingclip for 35 mm DIN rail, EN 60715 for heating body size - 4.7 x 2.4"; screw mounting with 2 mounting brackets for all heating body sizes, optional sideways mounting
Mounting PositionVertical Airflow (connection at bottom)
Storage Temperature-76 to +185 °F (-60 to +85 °C)
Operating / Storage humiditymax. 90 % RH (non-condensing)
Protection type / Protection classIP66 / I (grounded)
ApprovalsEPS 16 ATEX 1 109 X;
IECEx EPS 16.0048X; EAC

Models

Din Clip Mount Model No.Screw Mounting Bracket Model No.Hole Spacing XOperating
Voltage
Heating
Capacity
Pre-fuse
T (time-delay)
Dimensions
(DxWxH)
Weight
(approx)
02051.0-0002051.0-108.9"AC 230 V50 W0.5 A4.7 x 2.4 x 7.1"3.1 lbs
02051.9-0002051.9-108.9"AC 120 V50 W1 A4.7 x 2.4 x 7.1"3.1 lbs
-02052.0-1013.8"AC 230 V100 W1 A6.3 x 3.2 x 11.8"6.2 lbs
-02052.9-1013.8"AC 120 V100 W2 A6.3 x 3.2 x 11.8"6.2 lbs